Tutti i prezzi pubblicati sono in Euro ed IVA esclusa.
Tutti i prezzi pubblicati sono in Euro ed IVA esclusa
Aspiratore Fumi Pace Arm-Evac 250. PACE, saldatura - aspirazione fumi, apparecchiature.
QUOTAZIONE VALIDA ESCLUSIVAMENTE PER ORDINI ONLINE CON PAGAMENTO ANTICIPATO
Accessori 8886-0765-P1 non inclusi
Microprocessor controlled with an easy-to-read LED filter condition monitor that changes color when the filter needs to be changed. Unit increases pump speed as filter becomes loaded. Self-calibrates to specific arm configurations. Three-speed air flow adjustment, electronic air flow sensor. Flow rate 510 m3/h.
Includes Pre-filter, General Purpose combination filter and power cord.
• Power Requirements: 230VAC, 50 Hz 1.38 Amps
• Dimensions: 393mm H x 282mm W x 365mm D
• Weight: 14 Kg
• Sound Level: 58 dBA
• Number of Inlets: Two 75mm
• Flow Rate w/General Purpose Filter: Single Inlet: 288 m3/h (170 cfm), Dual Inlet: 170 m3/h (80 cfm) per inlet
• # of Collection Accessories: Four 45mm (1.75\\") or 50mm(2\\") or Two 75mm (3\\")
• Maximum Duct Run: 5m per inlet
• System Options: Silencer/Mobile Cart
• Standard Primary Filter: General Purpose Filter
• Filtration Options: General Purpose Filter, Cleanroom Filter, Adhesive Filter, Extended Life Filter, Economy Filter
Nota tecnica
Il filtro primario serve a trattenere le particelle di dimensioni maggiori in modo da preservare nel tempo il filtro HEPA che è strutturato per trattenere particelle fino al centesimo di micron.
La frequenza della sostituzione è in funzione dell’ambiente: tanto più la zona di lavoro è polverosa o il sistema capta particelle di grasso o olii (8-10 micron), quanto più spesso va sostituito.
Trattandosi di un filtro meccanico, è possibile capire all’inizio quanto sia pieno dalla perdita di efficienza del sistema (il filtro esausto funge da barriera). Normalmente in un ambiente tipo laboratorio in cui si saldi 8 ore al giorno con una lega contenente flussante di buona qualità si può sostituire il filtro ogni 15-20 giorni.
Il filtro combinato HEPA/carbone attivo serve per trattenere le particelle più piccole ed effettuare la degasificazione; (l’aria fuoriesce filtrata al 85%).
Normalmente, nelle condizioni sopra descritte e tenendo controllato il filtro primario, la sostituzione si effettua ogni 18-24 mesi.
Comunque, trattandosi di un filtro meccanico, non sussiste il pericolo che perda di efficienza mandando in ambiente particelle tossiche.
Alla peggio la barriera di contaminante ostruisce completamente il passaggio dell’aria e l’aspirazione viene meno... è arrivato il momento di sostituirlo.
Contattaci:
QUOTAZIONE VALIDA ESCLUSIVAMENTE PER ORDINI ONLINE CON PAGAMENTO ANTICIPATO
Accessori 8886-0765-P1 non inclusi
Microprocessor controlled with an easy-to-read LED filter condition monitor that changes color when the filter needs to be changed. Unit increases pump speed as filter becomes loaded. Self-calibrates to specific arm configurations. Three-speed air flow adjustment, electronic air flow sensor. Flow rate 510 m3/h.
Includes Pre-filter, General Purpose combination filter and power cord.
• Power Requirements: 230VAC, 50 Hz 1.38 Amps
• Dimensions: 393mm H x 282mm W x 365mm D
• Weight: 14 Kg
• Sound Level: 58 dBA
• Number of Inlets: Two 75mm
• Flow Rate w/General Purpose Filter: Single Inlet: 288 m3/h (170 cfm), Dual Inlet: 170 m3/h (80 cfm) per inlet
• # of Collection Accessories: Four 45mm (1.75\\") or 50mm(2\\") or Two 75mm (3\\")
• Maximum Duct Run: 5m per inlet
• System Options: Silencer/Mobile Cart
• Standard Primary Filter: General Purpose Filter
• Filtration Options: General Purpose Filter, Cleanroom Filter, Adhesive Filter, Extended Life Filter, Economy Filter
Nota tecnica
Il filtro primario serve a trattenere le particelle di dimensioni maggiori in modo da preservare nel tempo il filtro HEPA che è strutturato per trattenere particelle fino al centesimo di micron.
La frequenza della sostituzione è in funzione dell’ambiente: tanto più la zona di lavoro è polverosa o il sistema capta particelle di grasso o olii (8-10 micron), quanto più spesso va sostituito.
Trattandosi di un filtro meccanico, è possibile capire all’inizio quanto sia pieno dalla perdita di efficienza del sistema (il filtro esausto funge da barriera). Normalmente in un ambiente tipo laboratorio in cui si saldi 8 ore al giorno con una lega contenente flussante di buona qualità si può sostituire il filtro ogni 15-20 giorni.
Il filtro combinato HEPA/carbone attivo serve per trattenere le particelle più piccole ed effettuare la degasificazione; (l’aria fuoriesce filtrata al 85%).
Normalmente, nelle condizioni sopra descritte e tenendo controllato il filtro primario, la sostituzione si effettua ogni 18-24 mesi.
Comunque, trattandosi di un filtro meccanico, non sussiste il pericolo che perda di efficienza mandando in ambiente particelle tossiche.
Alla peggio la barriera di contaminante ostruisce completamente il passaggio dell’aria e l’aspirazione viene meno... è arrivato il momento di sostituirlo.